Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/15/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/09/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 09/08/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TIGHTEN H.D.'S AT KITCHEN SINK WALL 2) PROTECT HVAC LINES AT WEST WALL TOP PLATES WITH APPROPRIATE METAL 3) SHIM WEST WINDOW TRIMMER 4) BLOCK BETWEEN TOPS OF UPPER STRINGERS 5) ADD 2 X UNDER NORTH 2ND FLOOR BAND JOIST-SOUTH OF ENTRY 6) SHIM BONAD JOIST (SAME AS #5) UNDER 2 MID-SPAN POSTS 7) NEED DWV TEST 8) SECURE GREEN WIRE IN CEILING AND BANG PLATE IT AT STRAIR LANDING 9) FRAME FOR PLUMBING IN 1ST FLOOR SOUTHEAST ROOM CLOSET AND BANG PLATE GREEN WIRES IN EVERYWHERE 10) GROUND METAL BOX IN SOUTHEAST ROOM SWITCH 11) DOUBLE TRIMMERS IN ENTERTAINMENT NOOK 12) OVER NOTCHED TOP PLATES IN 1ST FLOOR SOUTH BATH AND BANG PLUMBING WHERE NEEDED 13) FHA STRAP TOP PLATES IN GARAGE AT OVER NOTCHES 14) FINISH MECH PLATFORM |