Permit: T03CM02400

Parcel: 136327740

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/16/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/25/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/1) need to replace all pa's that are installed in wrong location, and inproper installation
11/19/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) HOLDOWNS FRONT OF GARAGE OVERSPALLED NEED APPROVED ENGINEERING 2) 2'-8" B-BRACED WALL PANELS IN FRONT ENTRY ONE HOLDOWN EACH SIDE NOT PER DETAIL 3) EXPOSE POST TO BEAM CONNECTION AT FRONT PATIO, COMPLY WITH DETAIL 3-7 4) ANCHOR BOLTS MISSING AT PATIO POSTS 5) HOLDOWNS AT NORTHWEST PATIO AREA NOT PER PLAN 6) COMPLY WITH HEADER SCHEDULE FOR WINDOWS AT RIGHT AND LEFT SIDE OF FRONT ENTRY 7) STOPPED INSPECTION
11/13/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) PROVIDE LEDGERS OR REVISED DETAIL ON CONNECTIONS OF HANGERS TO WALL
11/10/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*