Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/26/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 06/25/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*10/DTI - SHEAR WALL MUST CONNECT TO BOTTOM CHORD OF TRUSSES. OK TO DRY IN. |
| 06/23/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) FHA STRAPS REQUIRED ON ALL SILL PLATE CUTS/NOTCHES GREATER THAN 40 PERCENT IN DEPTH AND AT PLUMBING LOCATIONS 2) NO TRUSS DRAWINGS ON SITE-TRUSS BRACES MISSING 3) CROSS BRACE TRUSSES EVERY 25 FEET 4) 10/DT1 NOT COMPLIED WITH 5) SHEARWALL 3 HOLDOWN IN WRONG LOCATION |