Permit: T03CM02395

Parcel: 137313700

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/26/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/25/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*10/DTI - SHEAR WALL MUST CONNECT TO BOTTOM CHORD OF TRUSSES. OK TO DRY IN.
06/23/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) FHA STRAPS REQUIRED ON ALL SILL PLATE CUTS/NOTCHES GREATER THAN 40 PERCENT IN DEPTH AND AT PLUMBING LOCATIONS 2) NO TRUSS DRAWINGS ON SITE-TRUSS BRACES MISSING 3) CROSS BRACE TRUSSES EVERY 25 FEET 4) 10/DT1 NOT COMPLIED WITH 5) SHEARWALL 3 HOLDOWN IN WRONG LOCATION