Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/30/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
06/26/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*1)USE MINIMUM 10D HANGER OR COMMON NAILS IN HANGERS AT GARAGE GIRDER TO HIP JACKS. YOU INSTALLED 8D'S. 2) TWO BLACK AREAS MARKED ON ROOF TO NAIL OF WEST SIDE AT VERY FRONT OK TO DRY IN 3) NAIL OFF TWO HD'S AT FRONT WALL |