Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/06/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/02/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) LATH SEAL PENETRATIONS AROUND EACES AND TAPE MISSING ON SEAMS 2) RE-ROUTE ROMEX AND STAPLE AT RIGHT SIDE OF SGD AND NAIL PROTECT WITHIN 1 1/4 FROM EDGE OF STUD 3) NO TEST ON DWV'S UPSTAIRS 4) STAPLE ROMEX AT HALL BATH 5) CONDENSATE LINE NOT GLUED 6) MISSING ANCHOR BOLT 7) WATER HEATER FLUE MISSING 8) FIRE BLOCK MISSING AT STAIRS, AND WATER HEATER PLATFORM 9) STAIR ? MISSING CLIPS AND RED HEAD AT GREEN PLATE |