Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/21/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/17/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0160*/ 1) POST AT STAIR-1ST FLOOR 2) NAIL PLATE WATER IN GARAGE AND KITCHEN 3) BLOCK TRUSSES PER DETAIL-SHEAR #9 4) SECURE AB'S 5) NAIL BLOCKING PANELS TIGHT BETWEEN TRUSS AT GARAGE SHEAR 6) COMPLETE DETAIL AT LEDGER NEAR ENTRY 7) INSTALL DETAIL 9 SD2 AT ALL LOCATIONS 8) LEAK AT YARD WATER LINE 9) REPAIR TOP PLATE IN POWDER ROOM AND AT CONDENSATE 10) ADD AB'S UNDER STAIR AT SOLE WITHIN 12" OF END 11) FIRE STOP STAIR STRINGER AT BOTTOM 12) NAIL PLATE SOLE AT UPPER FLOOR PER SHEAR SCHEDULE 13) SEAL 2ND FLOOR PENETRATIONS |