Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/28/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* ITEMS #3, 4, 5, 6 FROM 7/25/03 NOT COMPLETED. NEXT FAILURE WILL REFEE |
| 07/25/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO DWV WATER TEST 2) NO POTABLE WATER TEST 3) W/C REQUIRES 15" CLEARANCE CENTER LINE TO TUB 4) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF STUD WALL SURFACE 5) HEADERS MUST BEAR ON TRIMMERS 6) FHA STRAP ALL PLATE CUTS 6-16D NAILS EACH SIDE 7) HD'S NOT SECURE |