Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/10/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/09/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0160* 1) BLOCK EDGES AND NAIL SHEAR 5. 2) POST 3-2 X @ GARAGE WALL. 3) SECURE HOLD DOWNS 4) POST @ PATIO 4 X4. 5) NAIL PLATE COPPER IN GARAGE. 6) SEPARATE ROMEX AND COPPER. 7) NAIL PLATE IN HALL BATH. 8) REPAIR OVERNOTCHED STUDS IN BEARING. |