Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/04/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 07/07/2003 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*1) WASTE & VENT SYSTEM & OVERHEAD WATER DIST IS OK IN WALLS ONLY IN LB AREA. 2) SOIL WATER TEST IS OK. 3) 50LB AIR TEST ON WATER DIST IS OK. 4) NOTE:2" HORIZONAL VENT CAN NOT EXCEED 1/3 OF MAX ALLOWBLE LENGHT SE SEC TABLE 7-5 94 UPC. 5) OK TO DRYWALL WALLS ONLY. |