Permit: T03CM02264

Parcel: 122172850

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM02264

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2003 FRAMING Approved IVRS - Inspection 0000*
06/19/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) REMOVE PEX 12" AWAY FROM RECESSED LIGHTS 2) PROTECT PLUMBING THRU-OUT
06/16/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PLAN, PERMIT AND PREVIOUS INSPECTION RESULTS MUST BE ON SITE FOR INSPECTION
06/13/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) WATER LINES (WIRSBO) REQUIRES 12" CLEARANCE FROM RECESSED LIGHTS 2) DWV'S AND WATER LINES FAILED TEST 3) EXHAUST FAN MISSING FLAPPER IN HALL BATH 4) TERMINATE EXHAUST FANS TO OUTSIDE 5) REMOVE ROOF ELECTRIC FROM AROUND DRYER VENT 6) SINGLE WALL NOT ALLOWED IN ATTIC AT DRYER VENT