Permit: T03CM02260

Parcel: 136327320

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/01/2004 FRAMING Approved IVRS - Inspection :*
05/18/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) INCORRECT INFORMATION ON EXISTING PORCH BEAM, LOOKS LIKE APPROX 4 7/8 X 13"/14" LESS THAN 16", COVERED WITH STUCCO, LOOK UP ORIGINAL PLAN, SPAN 22'-7" NOT 21'-0" 2) REPLACE ALL 2 X FREEZE BLOCKS 3) WHAT TYPE POST HARDWARE DID YOU USE UNCOVER ON USE THE CORRECT NAIL, PER MANUFACTURER 4) YOU HAVE EIGHT OUTLETS, 5 CAN LIGHTS, 2 EXISTING AT OLD PORCH, 3 CEILING FANS, PLAN SHOWS A HOME RUN TO SERVICE, I BELIEVE YOU TIED INTO EXISTING CIRCUIT, WHICH ALREADY HAS A LIGHTING LOAD. YOU NEED A HOME RUN TO SERVICE PANEL 5) NO BEARING FOR 2ND FROM END RAFTER NORTH, NEED BETTER CONNECTION BARGE RAFTERS