Permit: T03CM02256

Parcel: 116214340


Addresses:

527 S STEPHANIE LP

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/13/2004 FRAMING Approved IVRS - Inspection :*/ 1) REINSPECT 2) PARTIAL HOLDING APPROVALS UNTIL WEST WALL SETBACKS VERIFIED 3) WILL NEED VERIFICATION OF WEST WALL (FINISHED STUCCO SURFACE) LESS TAHN 3' TO P/L. NO OPENINGS ALLOWED; MUST FIRE RATE 4) WILL NEED FIRE RATING ON S.E. CORNER LESS THAN 3'
05/05/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 5 1/8 Y12 GLU LAM REQUIRED AT GARAGE 2) FIREPLACE CAHSE AT ENTRY FRONT BATH 3) A.B. AT GARAGE REQUIRED AT FRONT ENTRY 4) W. WALL BY GAS LINE. FIRE WALL MISSING AT REAR SLIDING 5) REVISE PLAN TO SHOW GAS LINE TO RANGE AND FIREPLACE 6) SECURE FAN BOX AT CENTER HOLES AT REAR PORCH 7) PANEL NOT MADE UP 8) PA FOR PRESSURE TEST UNTIL PLAN IS REVISED 9) FIREBLOCK CAHSE AT MECH ROOM 1) SUPPORTING POST AT HDR AT STAIR WALL SHALL CONTINUE TO BOTTOM FLOOR
03/15/2004 FRAMING Not ready for Inspection IVRS - Inspection 0000*