Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM02226

Parcel: 133552300


Addresses:

9565 E 22ND ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM02226

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/26/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*/1) EXTERIOR DRINK FOUNTAIN OK PER APPROVED PLAN CORRECTIONS TO PLANS ON SITE. CORRECTIONS MADE 2) 2-BACK FLOW CERTIFICATIONS 3) 1-BACTERIA REPORT FOR WATER SYSTEM. TURNED IN WITH FINAL
02/12/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
02/03/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ WTR TEST OF GREASE INTERCEPTOR OK.
01/14/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) WATER TEST ON 4" PIPING FROM INSIDE BLDG TO GREASE TRAP ? AND TO TIE INTO BLDG DRAIN-OK. WILL NEED TO SEE CITY APPROVED PLAN FOR CHANGE TO PIPING, WATER TEST OF TRAP, WITH WRITTEN APPROVAL FOR SIDE ENTRY INTO GREASE TRAP
01/09/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ H20 FOR DRINKING FOUNTAIN IS APPROVED. SANITARY DRAINAGE FOR DRINKING FOUNTAIN WILL REQUIRE CONNECTION TO SANITARY SEWER WITH CITY APPROVED PLAN.
01/06/2004 PLUMBING - ROUGH, SOIL Partial Approval ADDITION OF MOP SINK - PARTIAL APP.
11/10/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 90 PSI AIR TEST ON 2" H2O SUPPLY FOR BLDG AND 1" FUTURE BACK OUT OF BLDG. OK.
11/04/2003 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE INSTALL END OF LINE 4" CLEAN OUT IN ALL RESTROOMS 2) PLEASE INSTALL IN LINE CLEAN OUT IN RUNS OVER 100' IN LENGTH 3) PLEASE INSTALL 2 WAY CLEAN OUT AT POINT OF BLDG DRAIN AND SEWER CONNECTION 4) PLEASE PROVIDE VERIFICATION OF ABS PIPING TO 5' OF EXTERIOR OF BLDG 5) PLEASE PROVIDE CITY APPROVED DRAWINGS FOR ADDITIONS TO ROUGH SOIL PIPING AND CHANGES TO EXISTING APPROVED PLAN