Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM02191

Parcel: 103183610

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM02191

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/12/2003 FRAMING Approved IVRS - Inspection 0000*
08/05/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) TEST WATER AND WASTE 2) COMPLETE LATH 3) U-VALUES AT ALL OPENINGS
08/04/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/01/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) AB'S 16" ON CENTER AT GARAGE WALL 2) STRAP TOP PLATES AT 3" WASTE, WATER 3) FIRE STOP STAIR STRINGER 4) 30" CLEAR HEADROOM AT ATTIC ACCESS, (RELOCATE OVERFRAME KICKER) COMPLETE SEALANT AT VAPOR BARRIER