Permit: T03CM02177

Parcel: 138243320

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/18/2003 FRAMING Approved IVRS - Inspection 0000*
08/14/2003 FRAMING Denied IVRS - Inspection 0935*/ 1) ANCHOR BOLTS LOOSE THROUGHOUT 2) NO DWV WATER TEST 3) SHIM HEADERS 4) HOLDOWNS LOOSE 5) GLUE LAM BEAM NOT CONNECTED TO POST KITCHEN 6) PLUMBING OUTSIDE OF WALL KITCHEN 7) FHA STRAPS REQUIRE 6 NAILS EACH SIDE WITH STRAPS INSIDE AND OUT AT TOP PLATE CUTS 8) ANCHOR BOLT MISSING KITCHEN 9) FIRE BLOCKS MISSING AT STAIR 10) 1" CLEARANCE REQUIRED TO COMBUSTIBLES AT WATER HEATER 11) STOPPED INSPECTION, TOO MANY ITEMS 5TH INSPECTION REQUEST, THIRD FAILURE, REFEE
08/12/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) HOLDOWN NUTS-LOOSE 2) UNABLE TO INSPECT HOUSE AND GARAGE EAST WALLS MOVE DRYWALL 3) DAMAGED WIRES AND LOOSE BOX LIVING ROOM ELECTRIC 4) FIRE BLOCK STAIRS 5) PROVIDE BACKING FOR STAIR HAND RAILS 6) EXTERIOR WALL SECOND FLOOR BOTTOM PALTE NOT NAILED PER CODE
08/11/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/08/2003 FRAMING Denied IVRS - Inspection 0950*
08/07/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*