Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM02126

Parcel: 11304041C


Addresses:

1175 E KLEINDALE RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
09/11/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
09/09/2003 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/1) SANITARY TEE NOT PERMITTED IN HORIZONTAL POSITION. 2) VENT MUST BE TAKEN OFF ABOVE CENTER LINE OF HORIZONTAL WASTE LINE. 3) FLAT VENTING ONLY PERMITTED WHERE REQUIRED BY STUCTURAL CONDITIONS. 4) PRIOR TO EXCAVATION AND PRE-SLAB INSPECTIONS, YOU MUST PASS ROUGH PLUMBING INSPECTION.