Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2004 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 06/11/2004 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PLAN CALLS FOR MECHANICAL FIRE PLACE MASONRY FIRE PLACE INSTALLED. PROVIDE CITY OF TUCSON APPROVED PLAN FOR MASONRY FIRE PLACE INCLUDING REQUIRED FOUNDATION AND DETAILS FOR MINIMUM CLEARANCE TO COMBUSTIBLES 2) ELECTRIC IS NOT INSTALLED PER PLAN CANNOT APPROVE FRAME UNTIL ELECTRIC IS INSTALLED 3) PROVIDE H2.5 CLIPS AT ALL RAFTER BEARING POINTS 4) PLAN CALLS FOR MASONRY CONSTRUCTION ON WEST WALL PRESENTLY METAL FRAME CONSTRUCTION WITH MASONRY COLUMNS 5) REVISE PLOT PLAN TO SHOW APPROXIMATE 8 X 24 BLDG LOCATED 18" FROM HOUSE AND CONNECTED TO EXISTING HOUSE ROOF 6) PLUMBING IS NOT COMPLETE. EXPOSE CONNECTION TO EXISTING PLUMBING |