Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02075
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/03/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
07/02/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED METAL UNDER GARAGE POST 2) FIX TUB LEAK 3) JOINT AT SHEATHING SHED TO GABLE TIE TRUSS/TO WALL EACH TRUSS A.35 MISSED NAILS ON TOP TAB, CLIP H2.5 4' ON CENTER LEDGERS | |
06/30/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION DOUBLE BLOCK AT BEAM 2ND FLOOR TO SUPPORT POST LOAD ON FLOOR 2) ROMEX AGAINST BOTH FLUES 3) WAS LEAK IN TUB FIXED, NO DWV TEST 4) WHERES THE PLATE (METAL) FOR POST HARDWARE GARAGE 5) TUB AND SHOWER PAN NOT INSTALLED | |
06/26/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*SAME AS LAST INSP | |
06/25/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |