Permit: T03CM02064

Parcel: 141172610

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM02064

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/15/2003 FRAMING Approved IVRS - Inspection 0000*
07/11/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SHIM UNDER 4 X 6, GIRDER IN GARAGE, STIFF LEG UNDER GIRDER AT GARAGE NORTH WALL
2) TIGHTEN A.C. H.D.'S
3) FRONT DOOR BANG PLATE 4) AT ALL MAS, STRAPS NOT INSTALLED CORRECTLY ALL NAIL HOLES FILLED INSTALL A.B. RETRO FIT PER PLAN ? BANG PLATE TUB WATER LINES
4) NAIL PROTECT COPPER LINE AT GARAGE
5) MISSING STUDS UNDER DBL GIRDER TRUSS
6) NAIL PROTECT ELECTRIC AT DBL TOP PLATE BEDROOM 3
7) WATER LINES MUST BE 12" AWAY FROM RECESSED LIGHTS IN HALL
8) OK TO NET
9) DWVS & WATER LINE TEST PASSED
07/10/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*