06/26/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
06/24/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*1) GARAGE CLIPS A 3-5 AT LEDGER NOT INSTALLED 2) HANGERS AT LEDGER TO BE 16D COMMONS NAILS 3) DETAIL FOR REAR PORCH NOT ON PLAN | |
06/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* ITEMS NOT CORRECTED FROM PREVIOUST INSPECTION RE-CHECK B/K NAILING THRU-OUT | |
06/19/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NAIL BLKG BETWEEN TRUSSES PER PLAN 2) PROVIDE DETAIL FOR REAR PORCH FROM ARCHITECT OF RECORD 3) STRAP AND CLIP BEAM AT PORCH |