Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM02056
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/07/2003 | FRAMING | Approved | ||
06/24/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*OK TO INSULATE 1)LAST HOUSE TO HAVE M.A.S. MUDSILL ON SHEARWALLS WITHOUT APPROVAL. PROBLEM: SHEAR WALL IS ATTACHED PRIOR TO BEING BROUGHT TO JOB SITE. REQUIRES A HOLE TO BE KNOWCKED OUT TO ATTACH THE STRAP. STRAPS AREN'T BEING INSTALLED CORRECTLY TO THE B/PLATE. 52 MODEL 10' SHEAR WALL; 5 HOLES AT BOTTOM OF SHEAR | |
06/20/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) AT FRONT GABLE TRUSS SECURE TO TOP PLATE WITH CLIPS LIVING GABLE 2) NEED 3.5'S AT GARAGE LEDGER 1/A2 3) MASTER BEDROOM STUD OVER SPAN 4) MASTER BEDROOM SHEAR BOTTOM PLATES NOT SECURE PLATE CLIPS NOT INSTALLED CORRECTLY 5) FRONT DOOR PLATE NOT SECURE 6) NEED DWV TEST 7) EXHAUST FAN DAMPERS MISSING 8) SECURE WATER LINE FRONT BATH 9) ROMEX LOOP AT HALL RETURN DUCT ? 10) USE CORRECT NAILS IN GARAGE HANGERS 11) SHEAR TRANSFER NOT COMPLETE AT TOP PLATE GARAGE TO HOUSE 12) HOLE IN KITCHEN DINING FLOOR |