Permit: T03CM02050

Parcel: 141172300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM02050

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/22/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
07/21/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999* HOUSE IS ALREADY LATHED
06/26/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*1) NEED INSTRUCTION FROM ENGINEER OF RECORD HOW TO INSTALL MAS MUD SILL STRAPS ON SHEARED WALLS, WHEN WALLS ARE SHEARED OFF SITE PRIOR TO ERECTION, HOLES ARE BEING KNOCKED OUT WITH HAMMERS 2) ALSO A3-5 AT LEDGES ARE BEING DONE BY KNOCKING HOLES IN THE O.S.B. TO INSTALL A3-5. 3) USE CORRECT NAILS IN ALL HANGERS BEFORE ROOF LOADING 4) OK TO DRY IN ROOF-DON'T LOAD
06/24/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*1) USE 16D COMMONS AT GARAGE LEDGER & CORNER HANGER 2) HOLES IN ALL SHEAR WALLS (ASK ENGINEER)
06/23/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SHEER TRANSFERS NOT NAILED PER PLAN 2) LEDGER AT GARAGE NOT CLIPPED AT SHEAR AREA 3) TRUSS BLOCKS NOT NAILED FROMF TOP 4) OVER SPAN NORTH WEST WALL 5) OVER SPAN SOUTH WEST WALL 6) OVER SPAN GARAGE WALL AT WATER HEATER PLATFORM AREA 7) SAF-T STRAP NORTH EAST MISSING 2 NAILS AT KING STUDS