Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM02050
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
07/21/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* HOUSE IS ALREADY LATHED | |
06/26/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*1) NEED INSTRUCTION FROM ENGINEER OF RECORD HOW TO INSTALL MAS MUD SILL STRAPS ON SHEARED WALLS, WHEN WALLS ARE SHEARED OFF SITE PRIOR TO ERECTION, HOLES ARE BEING KNOCKED OUT WITH HAMMERS 2) ALSO A3-5 AT LEDGES ARE BEING DONE BY KNOCKING HOLES IN THE O.S.B. TO INSTALL A3-5. 3) USE CORRECT NAILS IN ALL HANGERS BEFORE ROOF LOADING 4) OK TO DRY IN ROOF-DON'T LOAD | |
06/24/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*1) USE 16D COMMONS AT GARAGE LEDGER & CORNER HANGER 2) HOLES IN ALL SHEAR WALLS (ASK ENGINEER) | |
06/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) SHEER TRANSFERS NOT NAILED PER PLAN 2) LEDGER AT GARAGE NOT CLIPPED AT SHEAR AREA 3) TRUSS BLOCKS NOT NAILED FROMF TOP 4) OVER SPAN NORTH WEST WALL 5) OVER SPAN SOUTH WEST WALL 6) OVER SPAN GARAGE WALL AT WATER HEATER PLATFORM AREA 7) SAF-T STRAP NORTH EAST MISSING 2 NAILS AT KING STUDS |