Permit: T03CM02009

Parcel: 126042990


Addresses:

942 N COLUMBUS BL

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/15/2004 BUILDING - FINAL Approved IVRS - Inspection :*
08/04/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PROVIDE PHYSICAL PROTECTION FOR #4 GROUND WIRE OR ANCHOR AT 12" ON CENTER 2) DRIVE GROUND RODS BELOW GRADE 3) INCORRECT COLOR CODE ON A/C CONDENSOR WIRE CANNOT BE WHITE. ADD RED TAPE EACH END 4) OUTSIDE HOSE BIB FUACETS REQUIRED ANTI-SIPHON VALVES 5) LABEL ALL CIRCUITS IN SUB-PANEL 6) SUB-PANEL REQUIRES AN ISOLATED NEUTRAL BAR 7) BLACK WIRES CANNOT BE GROUND OR NEUTRAL 8) ALL GARAGE ELECTRIC OUTLETS MUST BE GFCI PROTECTED 9) CARPORT HAS BEEN ADDED TO NORTH SIDE OF HOUSE. PROVIDE CITY OF TUCSON APPROVED PERMIT 10) FURNACE VENT NOT SECURE. 3 SCREWS 11) FURNACE "B" VENT PLUGGED WITH TAPE 12) SEAL CEILING PENETRATIONS AT FURNACE ROOM 13) BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOTHES CLOSETS 14) SHOWER WINDOW MUST BE SAFETY GLASS 15) SOUTH EAST EXISTING BEDROOM HAS EGRESS ELEMINATED BY COVERING WINDOW 16) EXISTING BEDROOMS MUST HAVE BATTERY OPERATED SMOKE DETCTORS