Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/03/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1) SOIL WATER TEST IS OK 2) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 3) OK TO BACKFILL TRENCH 4) NOTE: MUST PERM. CAP EXISTING CLOSET BEND BY MOP SINK |
| 07/02/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION |
| 06/30/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) WILL REQUIRE A REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM PRIOR TO INSPECTION AS REQUESTED 2) DO NOT COVER |
| 06/27/2003 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION 2) SEE NOTE #3 AS REQUESTED |
| 06/26/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) DRAWING WAS APPROVED IN ERROR CANNOT DISCHARGE ANY NON GREASE CONVOYING FIXTURES INTO GREASE TRAP 2) SEE SECTION: 1011.13 94 UPC FOR LOCATION AND REQUIREMENTS OF FLOW CONTROL 3) WILL REQUIRE A REVISED AND APPROVED DRAWING ON WASTE AND VENT SYSTEM PRIOR TO NEXT INSPECTION |