Permit: T03CM01961

Parcel: 130082390


Addresses:

3633 E 28TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/18/2004 FRAMING Approved IVRS - Inspection :*
09/29/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) RECOMMEND YOU LOOK FOR U EXP. ELECTRIC 2) DOOR JAMB AT MASTER BEDROOM NOT SECURED PROPERLY 3) DRAIN BOX FOR WASHER TO HIGH 4) COMPLETE A/C LINES
09/17/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) INSTALL WASHER TRAY PER DRAWING LEFT ON SITE 2) ADD C/O AT VERTICAL DRAIN WASHER 3) INSTALL MECH DROP FOR FURNACE TO BELOW DRYWALL 4) KITCHEN SINK VENT DO NOT GO HORIZONTAL UNTIL 6" ABOVE DRAIN BOARD, OR RUN VENT AT 45 DEGREE 5) INSTALL GATE OR BALL VALVE ON COLD SIDE OF H20 HTR 6) ADD STUD AT REAR DOOR, BACKING IN CORNER FOR DRYWALL AT PLUMBING WALL INSIDE CORNER 7) ISOLATE CU H20 SERV ALL CU. FROM DUCT 8) CAN'T FIGURE OUT WIRING SOME BOXES HAVE TO MANY WIRES 9) SECURE ALL H20 LINES HORIZONTAL AND VERTICAL 10) PLAN CALLS FOR 1" H20 SERVICE