06/03/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000*/ 1) WILL CHECK FOR HOLDOWNS AT INTERMEDIATE 2) ENGINEERED FOR FIXTURE | |
06/02/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
05/30/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) CHECK FOR OVERSPAN FRAMING 2) CLIPS MISSING NAILS 3) HOLD DOWNS EAST WALL NOT NAILED TO TWO KING STUDS 4) NAIL PORTECT COPPER LINES FOR CONDENSOR FROM OUTSIDE 5) NAIL PROTECT ELECTRICAL AND PLUMBING FROM OUTSIDE 6) STOPPED INSPECTION RECALL WHEN SUPERVISOR WALKS HOUSE | |
05/29/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) GIRDER TRUSS DOUBLE 2 X POSTS MUST EXTEND TO GROUND 2) 7/SD3 NOT COMPLIED WITH |