Permit: T03CM01953

Parcel: 140293550


Addresses:

3869 E EVENTIDE ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01953

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) WILL CHECK FOR HOLDOWNS AT INTERMEDIATE 2) ENGINEERED FOR FIXTURE
06/02/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
05/30/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CHECK FOR OVERSPAN FRAMING 2) CLIPS MISSING NAILS 3) HOLD DOWNS EAST WALL NOT NAILED TO TWO KING STUDS 4) NAIL PORTECT COPPER LINES FOR CONDENSOR FROM OUTSIDE 5) NAIL PROTECT ELECTRICAL AND PLUMBING FROM OUTSIDE 6) STOPPED INSPECTION RECALL WHEN SUPERVISOR WALKS HOUSE
05/29/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) GIRDER TRUSS DOUBLE 2 X POSTS MUST EXTEND TO GROUND 2) 7/SD3 NOT COMPLIED WITH