Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/08/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE-OK 2) PLUMBING FINAL-OK 3) OK FOR C OF O PENDING ANY OTHER INSPECTIONS 4) CONTRACTOR: PLEASE INSTALL VACCUM BREAKERS ON ALL HOSE BIBS |
| 08/06/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ROUGH AND INTERMEDIATE CORRECTIONS MADE - OK. 2) ALL FIXTURES TO BE CAULKED. 3) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 DEGREE WITHOUT ADDING A CLEAN OUT. 4) ONLY ONE SLIPNUT ALLOWED ON OUTLET SIDE OF TRAP. 5) INSTALL DISHWASHERS, MAKE CORRECTIONS AND RECALL FOR INSPECTION. |