Permit: T03CM01911

Parcel: 110101620


Addresses:

4980 E ASA CARR WY

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
07/31/2003 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*
07/16/2003 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*
07/09/2003 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999* 1 REMOVE STAPLES BEHIND HOME RUNS 2) EVALUATE DAMAGED GRAY WIRE AT HOME RUNS 3) BANG PLATE GARAGE ?? AT/ LAUNDRY VENT 4) SHIM HEADERS/TRIMMERS WHERE NEEDED 5) BANG PLATE PEX AT TOP PLATER WEST OF STOVE VENT 6) CORRECT DUCT RESTRICTION NORHT WEST OF FIREPLACE-IN CHASE. 7) REPLACE FIRE BLOCK AT BATH 8) SECURE WIRE AT MASTER SHOWER CEILING