Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM01911

Parcel: 110101620


Addresses:

4980 E ASA CARR WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/01/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/26/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF 6" WIDE OSB EAST OF FRONT DOOR 2) SHIM HEADERS/TRIMMERS WHERE NEEDED 3) TIE TO PLATES WHERE PATIO HIP GIRDER INTERSECTS 4) NO DIAGONAL BRACING AT 25' RUNS 5) MISSING BOTTOM STUD CLIPS AT SOUTH SIDE 6) MISSING HEADER CLIP ON EAST SIDE 7) NEED ALTERNATE HOLDOWNS FOR BLOW OUTS FOR INTERMEDIATE INSPECTION 8) STRAP BOTTOM PLATES AT PLUMBING CUTS BEFORE MESH