Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01911
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
| 06/26/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NAIL OFF 6" WIDE OSB EAST OF FRONT DOOR 2) SHIM HEADERS/TRIMMERS WHERE NEEDED 3) TIE TO PLATES WHERE PATIO HIP GIRDER INTERSECTS 4) NO DIAGONAL BRACING AT 25' RUNS 5) MISSING BOTTOM STUD CLIPS AT SOUTH SIDE 6) MISSING HEADER CLIP ON EAST SIDE 7) NEED ALTERNATE HOLDOWNS FOR BLOW OUTS FOR INTERMEDIATE INSPECTION 8) STRAP BOTTOM PLATES AT PLUMBING CUTS BEFORE MESH |