Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/17/2003 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) OK FINAL |
| 06/16/2003 |
ELECTRIC - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) APPROVED EXTENDER RINGS ARE NEEDED WHERE BOXES ARE MORE THAN 1/4" TO SURFACE 370.20 2) FILL UNUSED OPENING IN PANEL BOTTOM AND AT A/C #1 3) COVER TO BE WHEATHER PROOF WHEN PLUGGED IN 410357 4) PLEASE REMOVE EXPOSED CONDUCTORS BACK TO LAST SAGE JUNCTION BOX 5) SUPPORT CONDUIT AND TIGHTEN SEAL TIGHT FITTING FOR A/C 6) PLEASE OPEN EXHAUST FAN TO VERIFY DISCONNECTING MEANS |