Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/17/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/1) CORRECTIONS MADE OK. OK TO COVER ALL AREAS. |
| 07/16/2003 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
1) HORIZONTAL SECTION OF K.S. VENT TO USE APPROVED FITTINS-SWEEP 2) CORRECTIONS MADE-OK 3) DON'T FORGET LAVATORY WITH 135 DEGREE CHANGE OF TRAP ARM TO HAVE ADDITIONAL CLEANOUT WILL CHECK ON FINAL 4) OK TO COVER WALLS |
| 07/14/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST STRAP ALL HORIZONTAL VENTS REAR UNIT 2) CANNOT HAVE HORIZONTAL VENT BELOW FLOOD RIM LEVEL AT KITCHEN SINK REAR UNIT 3) MUST SEAL TRAP BOXES FOR TUBS WITH CONCRETE 4) 3" VENT AT MAIN RESTROOM NEEDS SAFETY PLATE |
| 07/11/2003 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NEED WATER TEST |