Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/09/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/08/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* 1) STILL NO TEST ON DWV SYTEM 2) STILL PEX TOO CLOSE TO ONE CAN LITE 3) FRAMING WITHELD FOR PLB/ELECT |
| 07/07/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* 1) NEED FIRE BLOCKING SEVERAL PLACES AT ENTERTAIMENT CENTER/ FIREPLACE 2) PEX LINES MUST BE MIN 12" FROM CAN LITES. 3) NO TEST ON WATER OR DWV SYSTEM |
| 07/03/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*NEED A-B IN SILL PLATE; S. GARAGE WALL RED X |