Inspection History: STUCCO MESH

Date Description Inspector Results Comments
04/01/2005 STUCCO MESH Approved IVRS - Inspection :*
03/16/2005 STUCCO MESH Partial Approval IVRS - Inspection :*
1) PROTRUSION (ELECTRIC BOXES AND PIPE) MUST BE CAULKED AT THE FOAM TO SEAL IT
2) ALL PIPES (PLASTIC AND COPPER) AND ELECTRIC, THAT PASSES WITHIN 1 1/4" OF THE FACE OF A STUD OR PLATE, MUST HAVE A NAIL PROTECTION PLATE INSTALLED
3) NEED A DWV (DRAINAGE, WASTE, VENT) TEST
4) SECURE HANGING WIRES
5) FIREBLOCK FURRED WALL
6) NEED GAS PIPING RUN
7) NEED COMBUSTION AND RELIEF AIR FOR HOT H20 HEATER