Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/14/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CALL FOR ANY AND ALL INSPECTIONS THAT HAVE NOT BEEN APPROVED 03040, 03075, 03090 SEE NOTE #2 USE APPROVED TAPPED CLEANOUT PLUGS TO RECEIVE COVER SCREW. MAKE CLEANOUT PLUGS WATER AND GAS TIGHT WITH THREAD SEALANT. USE LISTED PIPE CLAMP TO SUPPORT EXP. TANK ROTATE TANK TO PROVIDE ACCESS TO SHRADER VALVE. |
|
| 01/19/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* CALL FOR ALL INSPECTIONS THAT HAVE NOT YET BEEN APPROVED PROVIDE 6" FROM TOP OF URINAL TO CRITICAL LEVEL OF FLUSH O METER REMOVE CLEAN OUT COVER SO THAT THE USE OF APPROVED CLEAN OUT PLUGS CAN BE VERIFIED. PROVIDE CLEAN OUT ADAPTERS W/PLUGS AT EXTERIOR CLEANOUTS BACKFLOW CERTIFICATION REQUIRED TO FINAL YARD WATER LINE |