Permit: T03CM01878

Parcel: 11822097D


Addresses:

101 W 25TH ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/15/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* WATER TEST UNDERGROUND WASTE & VENT FROM END OF LINE CLEANOUT THRU BUILDING TO 4" OUTSIDE NORTH END OF BUILDING INCLUDING PIPE WRAPS & TRAP PRIMER INSTALL OK
03/14/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) READ NOTE # 2 AS REQUESTED. 2) DO NOT COVER.
03/10/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SOIL SYSTEM LOST WATER TEST
2) SHALL PROVIDE A DIRECTIONAL FITTING WHEN VENTING BELOW THE FLOOD RIM LEVEL AT P-4. THIS IS ONLY ALLOWED WHEN A STRUCTURAL CONDITION EXISTS. THIS IS NOT THE CASE HERE. SHALL ROUGH IN P-4 IN A CONVENTIONAL METHOD AS PER APPROVED PLANS