Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* WATER TEST UNDERGROUND WASTE & VENT FROM END OF LINE CLEANOUT THRU BUILDING TO 4" OUTSIDE NORTH END OF BUILDING INCLUDING PIPE WRAPS & TRAP PRIMER INSTALL OK | |
| 03/14/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) READ NOTE # 2 AS REQUESTED. 2) DO NOT COVER. |
|
| 03/10/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SOIL SYSTEM LOST WATER TEST 2) SHALL PROVIDE A DIRECTIONAL FITTING WHEN VENTING BELOW THE FLOOD RIM LEVEL AT P-4. THIS IS ONLY ALLOWED WHEN A STRUCTURAL CONDITION EXISTS. THIS IS NOT THE CASE HERE. SHALL ROUGH IN P-4 IN A CONVENTIONAL METHOD AS PER APPROVED PLANS |