Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/20/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK PLUMBING FINAL OK OK FOR C OF O PENDING ANY OTHER INSPECTION. |
|
| 04/17/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/13/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. HARD PIPE HOT SUPPLY TO BELOW CEILING ALL HOT TO BE INSULATED. 2. REMOVE COVER ON E.W.C FOR INSPECTION. 3. REQUIRE 6" FROM CRITICAL LEVEL TO TOP OF URINAL. 4. MAKE ALL CLEAN-OUTS ACCESSIBLE REMOVE TEST PLUG AND INSTALL COUNTER SINK TAPPED CLEANOUTS W/5/16" MACHINE SCREWS. |
|
| 01/23/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SHALL PROVIDE WATER TO THE BUILDING PRIOR TO FINAL INSPECTION |