Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/24/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/24/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV WATER TEST IS OK 2) WATER DISTRIBUTION IS OK 3) THIS INSPECTION IS FOR PLUMBING IN WALLS ONLY 4) OK FOR DRY WALL UPON BLDG INSPECTORS APPROVAL |
|
| 07/25/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO LOCATE SPEC BOOK OR PERMIT 2) PIPING IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES 3) HOT LINE INSTALLED BEFORE INSPECTION 4) TRAP PRIMER NOT INSTALLED 5) INSPECTION STOPPED |