Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM01848

Parcel: 137291410


Addresses:

5581 S OAK RIDGE DR

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/17/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
06/16/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) PROVIDE 100 SQUARE INCHES HIGH AND LOW COMBUSTION AIR FOR WATER HEATER 2) GAS PRESSURE TEST MUST BE A MINIMUM OF 10 PSI OR HIGHER FOR TEST. LESS THAN 10 PSI NOW 3) PROVIDE 1" CLEARANCE FROM CLASS "B" VERT TO COMBUSTIBLE (ROOF) MATERIAL 4) PRVOIDE A 10' HIGH WATER TEST ON DRAIN WASTE AND VENT SYSTEM 5) WRAP ALL ABS PLUMBING THAT WILL CONTACT CONCRETE