Permit: T03CM01814

Parcel: 120052080


Addresses:

4561 S 14TH AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/10/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/13/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 5 EACH BEARING STUD NOTCHED GREATER THAN 25 PERCENT FOR PLUMBING-YOU MUST ADD STUDS AT EACH NOTCHED STUD 2) YOU MUST PLUG THE DRAIN WASTE VENT PLUMBING AND FILL WITH WATER TO ROOF 3) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD WALL SURFACE 4) ANCHOR SHOWER EARED ANGLE