Permit: T03CM01796

Parcel: 111082560

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/04/2003 FRAMING Approved IVRS - Inspection 0000*
10/30/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) BLOCK DUCT BOOTS WHERE NEEDED 2) INSTALL FIRE BLOCK GASKET AT FIREPLACE 3) ADD RED HEADS WHERE NEEDED 4) SHIM HEADERS WHERE NEEDED 5) BANG PLATE WASHER PLUMBING 7) PATCH SOUTH SLAB AT PATIO DOOR 8) FINISH MESH TOP, BOTTOM AND RECAULK WHERE NEEDED
10/23/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) STUCCO LATH MUST BE NAILED TO STUDS AND PLATES AT 6" OC. 2) NAIL PROTECT ALL ELECTRIC WIRES WITHIN 1-1/4" OF WALL SURFACES. 3) FIREPLACE FIRE STOP INSTALLED UPSIDE DOWN. MUST HAVE 2" TO COMBUSTABLES AT 'B' VENT. 4) BREAK THRU TO MAIN HOUSE NOT COMPLETE. 5) HEADER SCHEDULE 60 OPENING SHOULD BE 2X8 HEADERS ON BEARING WALL. STOPPED INSPECTION TOO MANY ITEMS.
10/08/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) COMPLETE LATH BEFORE INTERMEDIATES 2) FILL ALL PLUMBING WITH WATER FOR TOP OUT TEST