Permit: T03CM01758

Parcel: 136154250


Addresses:

7718 E 35TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
02/25/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
01/30/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ NEED 50 AMP CIRCUIT TO RANGE.
01/22/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ RANGE WIRING - 8-3 ROMEX - RATED FOR 40 AMPS PLAN SPECIFIER.