Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01753
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
05/16/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL HORIZONTAL JOINTS REAR SHEAR 2) 2 NAILS PER PLATE, WIND BRACE 3) H2.5 LEDGER TO WALL LIVING ROOM 4) LEDGER OMITTED WEST WALL, NEED ALTERNATIVE-NOT DIAPHRAM CONNECTION 5) JOINT IN ROOF DECK LIVING AT LEDGER NEED MECHANICAL TIE 6) INSTALL ALL SMALL #3 SHEAR WALLS FRONT AND REAR CORNERS |