Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM01723

Parcel: 140106360

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/27/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/22/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STUDS NOTCHED GREATER THAN 25 PERCENT FOR BRACING REPLACE 2) HEADERS MUST BEAR ON TRIMMERS AND TRIMMERS ON BOTTOM PLATES 3) STUDS MUST BEAR TOP AND BOTTOM PLATES 4) CLIPS MUST HAVE ALL ROUND HOLES FILLED WITH NAILS