Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/27/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 05/22/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STUDS NOTCHED GREATER THAN 25 PERCENT FOR BRACING REPLACE 2) HEADERS MUST BEAR ON TRIMMERS AND TRIMMERS ON BOTTOM PLATES 3) STUDS MUST BEAR TOP AND BOTTOM PLATES 4) CLIPS MUST HAVE ALL ROUND HOLES FILLED WITH NAILS |