Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/18/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) OK FOR DRYWALL |
| 06/12/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON WASTE AND VENT SYSTEM 2) WATER SERVICE NOT CONNECTED 3) CAN ONLY HAVE (1) 90 DEGREE ON TRAP ARM FOR KITCHEN SINK 4) HORIZONTAL VENTS FOR KITCHEN SINKS MUST BE 6" ABOVE FLOOD RIM LEVEL 5) SEVERAL LOOSE PIPING FOR WATER 6) CAN NOT BUNDLE HOT AND COLD WATER 7) HOT WATER LINE IS EXPOSED OF FOOTER FRONT UNIT 8) NO APPROVED PLUMBING PLAN ON SITE |