Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/08/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/07/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GAS PRESSURE TEST AT 9, 10 POUNDS REQUIRED MINIMUM 2) REMOVE ROOFING MATERIAL AWAY FROM WATER HEATER FLU 1" REQUIRED MINIMUM FROM FLAMABLES 3) BLOCK MECH IN LAUNDRY ROOM 4) HOLDOWN IN LAUNDRY ROOM MISSING NAILS AND NUT 5) HOLDOWN IN BEDROOM EAST WALL NOT INSTALLED 6) STOPPED INSPECTION, HAVE SUPER WALLK HOUSE BEFORE, RECALL |
| 05/06/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSULATE BEHIND TUB EAST WALL 2) INSULATE BEHIND SHOWER AT MASTER BATH 3) COMPLY WITH DETAIL S1.1/11 OUTRIGGERS |