Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/05/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/04/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) DAMPER IN EXHAUST FAN LAUNDRY ROOM NOT WORKING 2) CONDENSATE LINE ABOVE WASHER BOX NOT PROTECTS 3) #3 FROM LAST INSPECTION NOT DONE #5, #6 AND #7 |
| 06/03/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) EXHAUST FAN IN LAUNDRY ROOM MISSING DAMPER 2) NAIL PROTECT DRYER VENT 3) NAIL PROTECT ELECTRIC WITH 1 1/4 FROM EDGES OF STUD THROUGHOUT HOUSE AND GARAGE 4) EXHAUST FAN IN MASTER BATH MISSING DAMPER 5) REPLACE BLOWN FIRE BLOCKS IN MASTER BATH 6) NAIL PROTECT WATER LINES ABOVE MASTER TUB NEED TO BE 12" AWAY FROM CAN LIGHT 7) WATER LINES ABOVE MASTER TUB NEED TO BE 12" AWAY FROM CAN LIGHT 8) PARTIAL 3035 FOR WATER LINE TEST 9) PARTIAL 4035 FOR REST OF INSPECTION PENDING TWO FANS 10) OK TO NET ONLY IF REPAIRS ARE EXPOSED FOR INSPECTION |