Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 04/30/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP CORNERS OF GABLE TRUSSES DOWN TO CORNER KINGS 2) TC CLIPS MIS-NAILED 3) H2.5'S NOT NAILED OFF IN REAR RIGHT BEDROOM 4) NAIL BIRD BOARDS THROUGH ROOF SHEATHING 5) PROVIDE PLANS/PERMIT AT INSPECTIONS 6) NEED CLIPS AT WEST END OF ENTRY TRUSSES |
| 04/29/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |