Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/06/2004 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 03/31/2004 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) MISSING RAFTER HANGERS AT LEDGERS, THRU OUT 2) VIGA LOGS AT BEARING ENDS WERE NOT INSTALLED PER PLAN, HAVE SLOT IN ENDS APPROVED 3) SEE RED MARKS ON ROOF DECK, MISSED NAILING AND H2.5 4) NAIL ITT.211.88-10D'S REQUIRED 83 SIMPSON 5) HEADER SIZE LIVING H-5 3-2 X 12 FLITCH BEAM-WRONG SIZE INSTALLED 6) H-6 HEADER FOYER, WRONG SIZE INSTALLED 7) H-5 HEADERS DELETED FRONT BATH, MISSING TJ HANGERS 8) CAN'T SEE A.35 AT 1/S4 ENTRY 9) NEED BEARING HEADER END, FOYER VIGA POST OTHER SIDE H-3 HEADER 10) NEED FULL BEARING UNDER 6 X 10 LIVING ROOM EXT. WALL 11) GAME ROOM, WINDOW REMOVED-NOT INSTALLED 12) COLUMN BASES NOT INSTALLED PER PLAN 13) NEED A CROSS SECTION OF DINING ROOM TO GREAT ROOM WALL |