Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01627
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
05/12/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL AT GARAGE CLEANOUT 4' SHEAR MARKED IN BLACK 2) STRENGTHEN FIREPLACE CHASE 3) TRUSS DRAWINGS NOT COMPLETE 3 PT BEARING | |
05/09/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTIONS | |
05/08/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION | |
05/07/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SHEAR TRANSFER TO BE DONE LIKE DETAIL 403/SD 2) SHIM ALL 3 PT BEARING 3) BLOCK ALL TRUSSES AT BEARING WALL, BEHIND FRIEZE BOARD 4) NEED COMPLETE SET TRUSS DRAWINGS 5) GAP IN ROOF DECK BAY WINDOW 6) LAST RAFTER AT EAST END OF PORCH NOT NAILED, TO ROOF DECK 7) 2 NAILS IN EACH PLATE TOP/BOT, WIND BRACE FINISH NAILING ALL |