Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM01627

Parcel: 141301830

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01627

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/13/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/12/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) NAIL AT GARAGE CLEANOUT 4' SHEAR MARKED IN BLACK 2) STRENGTHEN FIREPLACE CHASE 3) TRUSS DRAWINGS NOT COMPLETE 3 PT BEARING
05/09/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTIONS
05/08/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION
05/07/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHEAR TRANSFER TO BE DONE LIKE DETAIL 403/SD 2) SHIM ALL 3 PT BEARING 3) BLOCK ALL TRUSSES AT BEARING WALL, BEHIND FRIEZE BOARD 4) NEED COMPLETE SET TRUSS DRAWINGS 5) GAP IN ROOF DECK BAY WINDOW 6) LAST RAFTER AT EAST END OF PORCH NOT NAILED, TO ROOF DECK 7) 2 NAILS IN EACH PLATE TOP/BOT, WIND BRACE FINISH NAILING ALL