Permit: T03CM01593

Parcel: 117072000


Addresses:

726 S STONE AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/29/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*/ 1) ALL WORK COMPLETED WITHOUT INSPECTIONS APPROVAL 2) SPOT CHECK AREAS OF CONCERN 3) APPEARS ADEQUATE FOR PURPOSES INTENDED
04/21/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) SAME AS PREVIOUS REJECTION DATED 4/18/03
04/18/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NEED VERIFICATION OF ALL ASPECTS OF CONSTRUCTIVE FRAME, ELECTRIC, PLUMBING (ALL COVERED WITHOUT INSPECTION) 2) SECURE A.C. DISCONNECT SECURELY TO SHEET METAL ON ROOF 3) PAINT EXPOSED VENTS ON ROOF LATEX PAINT 4) INSTALL VACUUM BREAKER HOSE BIB (EXTERIOR) 5) MUST HAVE ONE HOUR RATED WALLS WEST AND NORTH PROPERTY LINES (MINIMUM 12" MASONRY PARAPET ABOVE ROOFING MATERIAL
04/17/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) GATES LOCKED, RECALL
04/10/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) PROVIDE PRESSURE RELIEVE LINE AT WATER HEATER 2) OUTLET AT NORTH END OF COUNTER MUST BE GFCI 30 PROVIDE ACCESS TO ROOF